RADIAL LEADED PTC
RB MODEL

E175689

50006513

FEATURES

  • Radial Leaded, high hold current, solid state
  • Operation current: 900mA~9A
  • Maximum Voltage: 30V
  • Temperature range: -40 to 85
  • Cured, flame retardant epoxy polymer insulating material meets UL 94V-0 requirement
  • Bulk packaging, tape and reel available on most models

APPLICATIONS

Ideal for low voltage power supply with a load to be protected:

  • Computers & peripherals
  • Security and fire alarm system
  • General electronics
  • Loud speakers
  • Automotive applications
  • Power transformers

PART NUMBERING SYSTEM

  ERF XX XXX XX X X X
   |   |  |   | | | |
   |   |  |   | | | +--- Z:RoHS Compliant
   |   |  |   | | +--- Special number:
   |   |  |   | |      0:Standard product
   |   |  |   | +--- Packing type:
   |   |  |   |      0:bulk
   |   |  |   |      2:tape & reel
   |   |  |   +--- Voltage rating: 30:30V
   |   |  +--- Current rating: 090:0.9A
   |   +--- Model:
   |        RB:Radial leaded devices, high hold current
   +--- Product Name: Resettable Fuse

MARKING SYSTEM

ELECTRICAL CHARACTERISTICS (23oC)

Part
Number

Hold
Current

Trip
Current

Max. Time
to trip

Maximum
Current

Rated
Voltage

Typical
Power

Resistance Tolerance

RMIN

R1MAX

IH, A

IT, A

at 5xIH

IMAX, A

VMAX, Vdc

Pd, W

RB090-30

0.90

1.80

5.9

40

30

0.6

0.070

0.22

RB110-30

1.10

2.20

6.6

40

30

0.7

0.050

0.17

RB135-30

1.35

2.70

7.3

40

30

0.8

0.040

0.13

RB160-30

1.60

3.20

8.0

40

30

0.9

0.030

0.11

RB185-30

1.85

3.70

8.7

40

30

1.0

0.030

0.09

RB250-30

2.50

5.00

10.3

40

30

1.2

0.020

0.07

RB300-30

3.00

6.00

10.8

40

30

2.0

0.020

0.08

RB400-30

4.00

8.00

12.7

40

30

2.5

0.010

0.05

RB500-30

5.00

10.00

14.5

40

30

3.0

0.010

0.05

RB600-30

6.00

12.00

16.0

40

30

3.5

0.005

0.04

RB700-30

7.00

14.00

17.5

40

30

3.8

0.005

0.03

RB800-30

8.00

16.00

18.8

40

30

4.0

0.005

0.02

RB900-30

9.00

18.00

20.0

40

30

4.2

0.005

0.02

IH=Hold current-maximum current at which the device will not trip at 23 still air.
I
T=Trip current-minimum current at which the device will always trip at 23 still air.
V
MAX=Maximum voltage device can withstand without damage at rated current.
I
MAX= Maximum fault current device can withstand without damage at rated voltage (V max).
Pd=Typical power dissipated from device when in the tripped state in 23 still air environment.
R
MIN=Minimum device resistance at 23.
R1
MAX=Maximum device resistance at 23 1 hour after tripping.

Typical time-to-trip-at 23oC

Thermal Derating Curve

RB Product Dimensions (UNIT:mm)

Part
Number

A

B

C

D

E

F

Maximum

Maximum

Typical

Minimum

Maximum

Typical

RB090-30

7.4

12.2

5.1

7.6

3.0

0.9

RB110-30

7.4

14.2

5.1

7.6

3.0

0.9

RB135-30

8.9

13.5

5.1

7.6

3.0

0.9

RB160-30

8.9

15.2

5.1

7.6

3.0

0.9

RB185-30

10.2

15.7

5.1

7.6

3.0

0.9

RB250-30

11.4

18.3

5.1

7.6

3.0

0.9

RB300-30

11.4

17.3

5.1

7.6

3.0

1.2

RB400-30

14.0

20.1

5.1

7.6

3.0

1.2

RB500-30

14.0

24.9

10.2

7.6

3.0

1.2

RB600-30

16.5

24.9

10.2

7.6

3.0

1.2

RB700-30

19.1

26.7

10.2

7.6

3.0

1.2

RB800-30

21.6

29.2

10.2

7.6

3.0

1.2

RB900-30

24.1

29.7

10.2

7.6

3.0

1.2

Note: Specifications subject to change without prior notice.