RADIAL LEADED PTC
HX/HU MODEL

E175689

50026469

FEATURES

  • Low hold current, Solid state
  • Radial-leaded product ideal for up to 60V/600V
  • Operation current: 0.08A~0.18A
  • Maximum voltage: 60V/250V/600V
  • Temperature range: -40 to 85
  • Cured, flame retardant epoxy polymer insulating material meets UL 94V-0 requirement
  • Bulk packing, tape and reel available on most models

APPLICATIONS

  • Network Equipment
  • Customer Premise Equipment
  • Modem / Information Technology Equipment
  • Satellite Receivers

PART NUMBERING SYSTEM

  ERF XX XXX XX X X X
   |   |  |   | | | |
   |   |  |   | | | +--- Z:RoHS Compliant
   |   |  |   | | +--- Special number:
   |   |  |   | |      0:Standard product
   |   |  |   | |      U:Unencapsulated part
   |   |  |   | +--- Packing type:
   |   |  |   |      0:bulk
   |   |  |   |      2:tape & reel
   |   |  |   +--- Voltage rating:
   |   |  |        V3:250V(int)
   |   |  |        V4:600V(int)
   |   |  +--- Current rating: 011:0.11A
   |   +--- Model:
   |       
HX:Radial leaded devices, low hold current
   |           (Disc type)
   |        HU:Radial leaded devices, low hold current
   |           (Rectangle type)

   +--- Product Name: Resettable Fuse

MARKING SYSTEM

ELECTRICAL CHARACTERISTICS (23oC)

Part
Number

Hold
Current

Maximum
Current

Max Oper.
Voltage

Max Int.
Voltage

Resistance Tolerance

RMIN

R1MAX

IH, A

IMAX, Amp

VMAX, Vdc

VI-MAX, Vdc

HX008-V3 U

0.08

3.0

60

250

14.0

33.0

HX008-V3

0.08

3.0

60

250

14.0

33.0

HX011-V3 U

0.11

3.0

60

250

5.0

16.0

HX011-V3

0.11

3.0

60

250

5.0

16.0

HU012-V3 U

0.12

3.0

60

250

6.0

16.0

HU012-V3

0.12

3.0

60

250

6.0

16.0

HU015-V3 U

0.15

3.0

60

250

3.0

12.0

HU015-V3

0.15

3.0

60

250

3.0

12.0

HU018-V3 U

0.18

10.0

60

250

0.8

4.0

HU018-V3

0.18

10.0

60

250

0.8

4.0

HU015-V4

0.15

3.0

60

600

6.0

22.0

HU016-V4

0.16

3.0

60

600

4.0

18.0

IH=Hold current-maximum current at which the device will not trip at 23 still air.
I
T=Trip current-minimum current at which the device will always trip at 23 still air.
V
MAX=Maximum voltage device can withstand without damage at rated current.
I
MAX= Maximum fault current device can withstand without damage at rated voltage (V max).
Pd=Typical power dissipated from device when in the tripped state in 23 still air environment.
R
MIN=Minimum device resistance at 23.
R1
MAX=Maximum device resistance at 23 1 hour after tripping.

Typical time-to-trip-at 23oC

Thermal Derating Curve

HX/HU Product Dimensions (UNIT:mm)

Part
Number

Fig

A

B

C

D

E

Maximum

Maximum

Typical

Minimum

Maximum

HX008-V3 U

1

5.1

9.1

5.0

4.7

3.8

HX008-V3

1

5.8

9.6

5.0

4.7

4.6

HX011-V3 U

1

5.9

9.4

5.0

4.7

3.8

HX011-V3

1

6.8

9.9

5.0

4.7

4.6

HU012-V3 U

2

6.0

10.0

5.0

4.7

3.8

HU012-V3

2

6.5

11.0

5.0

4.7

4.6

HU015V3 U

2

6.0

10.0

5.0

4.7

3.8

HU015V3

2

6.5

11.0

5.0

4.7

4.6

HU018-V3 U

2

10.4

12.6

5.0

4.7

3.8

HU018-V3

2

10.9

12.6

5.0

4.7

4.6

HU015-V4

2

13.5

12.6

5.0

4.7

6.0

HU016-V4

2

16.0

12.6

5.0

4.7

6.0

Note: Specifications subject to change without prior notice.